OPERATING SYSTEM:
|
Windows XP / Vista Ultimate
|
| |
|
POWER REQUIREMENTS:
|
100/120 VAC 50/60 Hz 2.5 A nominal; 200/240 VAC 50/60 Hz 1.3 A nominal
|
| |
|
Standard:
|
Bruce, Modified Bruce, Modified Balke, Naughton, USAF/SAM 2.0, USAF/SAM 3.3, Persantine (pharmacological)
|
| |
|
PATIENT MODULE:
|
AHA 10-electrode with pinch or snap connectors IEC 10-electrode with pinch or snap connectors (available for International only)
|
| |
|
Capability:
|
True 12-lead
|
|
Gain:
|
5 mm/mV, 10 mm/mV, 20 mm/mV
|
|
Lead Groups:
|
Standard (Mason-Likar), Cabrera 12-lead, Frank, Canadian Bipolar
|
|
Display:
|
3 channels
|
|
Performance Standard:
|
AAMI-EC II: gain accuracy, frequency response, CMRR, system noise, dynamic range, and input impedance
|
| |
|
DISPLAY AND ANALYSIS FILTERS:
|
Muscle artifact filter, baseline wander filter, 40 Hz low pass, line frequency. All filters can be turned on or off by the user
|
| |
|
Heart Rate:
|
Computation 6 second average updated every 2 seconds
|
|
ST Parameters:
|
Level and slope
|
|
Reference Point:
|
J Junction (QRS offset), user-selectable
|
|
QRS Detection:
|
ASVV (Absolute Spatial Vector Velocity), user can select any three leads
|
|
Beat Detection:
|
Enhanced Quinton Stress algorithm for improved beat detection
|
| |
|
VISUAL AND AUDIO NOTIFICATIONS:
|
ST level elevation, ST level depression, target HR achieved, ectopic rate, diastolic BP, systolic BP, systolic BP drop, heart rate, stage changes, max heart rate and target HR achieved
|
| |
|
In-Test:
|
12-Lead, average beat, 1-page write screen, continuous write screen, ectopic detail
|
|
Final:
|
Summary, tabular, worst case, average beats, in-test reports and peak exercise Reports can be viewed, printed, saved in PDF format, e-mailed or faxed. XML format for data export to other systems
|
| |
|
OUTPUTS:
|
TTL pulse for QRS detection (lead is user- selectable); 3 user-selectable analog outputs using any ECG lead
|
| |
|
Treadmills:
|
TM 55/65, ST 55/65 (Upgrade kit required)
|
|
Ergometers:
|
Corival, Ergoselect, Rehcor
|
|
Blood Pressure Monitors:
|
Colin BP412, SunTech Tango+
|
| |
|
AVAILABLE PRINTER:
|
Optional Laser printer: compact HP laser printer with high quality print
|
| |
|
NETWORK INTERFACE:
|
Optional Microsoft compatible networking for file storage, distribution and email
|
| |
|
EXPORT/COMMUNICATION PROTOCOL/FORMAT:
|
XML, PDF
|
| |
|
REMOTE TECHNICAL SERVICE INTERFACE:
|
Remote service increases system uptime availability and decreases the user’s requirement to assist the troubleshooting process. Available via network or desktop connections (available only in the US)
|
| |
|
DISPLAY:
|
483 mm (19 in) LCD flat panel
|
| |
|
Operating temperature:
|
50°F to 77°F (10°C to 25°C)
|
|
Operating relative humidity:
|
20% to 80% non-condensing
|
|
Storage temperature:
|
-14.8°F to 104°F (-26°C to 40°C)
|
|
Storage relative humidity:
|
10% to 95% with condensation
|
|
Thermal paper storage:
|
at or below 77°F (25°C)
|
|
Electrodes storage:
|
at or below 86°F (30°C)
|
| |
|
SAFETY AND STANDARDS:
|
EN 60601-1, Type CF defibrillation proof applied part IEC 61000-4-6 IEC 61000-3-2 IEC 61000-4-2 IEC 61000-4-4 IEC 61000-4-8 IEC 61000-3-3 IEC 61000-4-3 IEC 61000-4-5 IEC 61000-4-11 RF emissions CISPR 11
|
| |
|
CART DIMENSIONS AND WEIGHT:
|
30 in x 22 in x 35 in (762 mm x 558.8 mm x 889 mm); 142 lb (64 kg)
|
| |
|
WARRANTY:
|
13 months
|